BlueWalker SNMP CP-504 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Síťové karty BlueWalker SNMP CP-504. BlueWalker SNMP CP-504 Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 99
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - NetAgent

NetAgent UPS SNMP Agent User’s Manual

Strany 2

4 Section3. NetAgent Models 3.1 NetAgent Models NetAgent II Model P/N Package Contents Internal/External 1/3 Ports 1/3 phasesCP504 CT504 1. 1Port

Strany 3 - Contents

5 DP532 DT532 1.Enternal NetAgent Mini with LCD Display 2. NetAgent Utility CD 3. User Manual 4. 5.3V DC adapter External *DT/CT version same dimensio

Strany 4

3.2 Pictures of NetAgent II NetAgent II(BP,CP/CT,DP/CT Series) CP504 CP503 BP506 BP505 NetAgent Mini (DP Series) DP520 DP522 DP532 6 DP

Strany 5

3.3 NetAgent Package Contents n NetAgent Utility CD, including: ♦ Netility:Configure NetAgent IP address, update firmware ♦ ClientMate:Windows, Linux,

Strany 6

3 Ports NetAgent (Internal / External) : LED Table Yellow Red Green Status Solid Off Solid Off Solid ON Power ON Flashing Solid ON Soli

Strany 7 - Chapter1. Introduction

3.5 NetAgent Mini Out looking NetAgent Mini External NetAgent Mini Internal Module Light signal application of NetAgent Mini - Status

Strany 8 - Section2. Applications

Chapter 2. NetAgent UPS Installation Before using the NetAgent, the proper hardware and software configuration is necessary. Hardware installation

Strany 9

Chapter 3. NetAgent, UPS and Network Connection NetAgent II and NetAgent Mini provides External and Internal model for different UPS interface requir

Strany 10 - Section3. NetAgent Models

Section2. Install the NetAgent Mini with UPS and Network NetAgent Mini - External NetAgent Mini -Internal oTo UPS nTo LANpTo DC Adapter nTo LA

Strany 11

Chapter 4. Using Netility Setup IP.Update Firmware Section1. Install Netility n Insert NetAgent Utility CD to the CD-ROM driver and execute Netili

Strany 12

User Guide for NetAgent Version 6.0 Firmware version 2.42 Copyright Information Copyright © 2000-2009, Mega System Technologies, Inc. All rights rese

Strany 13 - External NetAgent Mini

n Launch Device Click Launch Device or double click the NetAgent listed in the table to launch it. Enter the Account (Login Name) and Password (Login

Strany 14 - LED Table

For example, ) Set 81 as HTTP port number, then http://192.168.0.177:81 must be typed at the web address to proceed to Netagent UPS’s website. ) S

Strany 15

p Firmware Upgrade NetAgent offer convenient firmware upgrade function. When you are going to upgrade firmware, click Download Firmware from NetAge

Strany 16

Chapter 5. UPS Web management by NetAgent Section1. Introduction After finishing NetAgent installation, including hardware installation and IP setting

Strany 17

Section2. NetAgent UPS Web Interface Enter NetAgent UPS Web page,there are 4 main function items in the first Web page: 2.1 Information 2.2 Configura

Strany 18

2.1 Information Sub-Menu : 2.1.1 System Status 2.1.2 Basic Information 2.1.3 Current Status 2.1.4 Remote Control 2.1.5 Meter/Chart 2.1.6 Modem Statu

Strany 19 - Section2. Using Netility

2.1.1 System Status This page is to show NetAgent system information and Network settings. Values shown here are either provided by NetAgent itself or

Strany 20

2.1.2 Basic Information This page is to show UPS basic information. Values here are either provided by the UPS or they are user settings from the Conf

Strany 21

2.1.3 Current Status This page is to show the UPS current status. Users can choose an interval from the drop-down box to refresh the status readings.

Strany 22

10 Second Test This to perform 10 seconds UPS self test Deep Battery Test This function is to execute XX minute deep battery test Test Until Battery

Strany 23 - Section1. Introduction

Contents Chapter1. Introduction ________________________________________ 1 Section1. Features __________________________________________ 1 Section2. A

Strany 24

2.1.5 Meter/Chart This page displays temperature, capacity, load, voltage..etc of the UPS by appearing with meters/chart diagram. Fig.20 Meter/Chart

Strany 25

2.1.6 Modem Status (For 3 Ports NetAgent II only) This page displays Modem’s status and information. when 3 ports NetAgent II connects with modem. M

Strany 26 - Configuration pages

2.1.7 Environment Sensors-NetFeeler II 3 Ports NetAgent could be connected to NetFeeler II to detect the environmental status. NetFeeler II is to dete

Strany 27 - 2.1.2 Basic Information

2.2 Configuration Sub-Menu : 2.2.1 UPS Configuration 2.2.2 UPS On/Off Schedule 2.2.3 Network 2.2.4 SNMP 2.2.5 Email 2.2.6 SMS 2.2.7 Modem 2.2.8 WEB

Strany 28 - Fig.18 Current Status

2.2.1 UPS Configuration This page is to set the UPS configuration. Any wrong settings will cause incorrect display values or disconnection between the

Strany 29 - Fig.19 Remote Control

Critical Capacity (%) This section is to set the UPS critical battery capacity (shown as % )NetAgent will send warning messages when UPS low battery o

Strany 30 - 2.1.5 Meter/Chart

2.2.2 UPS On/Off Schedule This page is to schedule On/Off time for the UPS and Wake On Lan. Weekly Schedule This section is to set the time to tur

Strany 31 - Fig.21 Modem Status

2.2.3 Network This page is to set NetAgent Network settings. IP Address IP Address This section is to set NetAgent IP address. Subnet Mask Thi

Strany 32

Domain Name This is the Domain Name you have created from the above selected DDNS provider. Login Name This is the Login / Account name that you have

Strany 33

Fig.25 Network 33

Strany 34 - 2.2.1 UPS Configuration

2.1.3 Current Status______________________________________ 22 2.1.4 Remote Control ____________________________________ 22 2.1.5 Meter/Chart__________

Strany 35 - Critical Capacity (%)

2.2.4 SNMP This page is to set NetAgent SNMP settings so it can be used by a NMS ( Network Management System). (Eg: SNMPView, SNMPView can be fou

Strany 37 - 2.2.3 Network

Device Connected This section is to set the usage power and connection status of other devices which connects to the same UPS as NetAgent uses. Fig

Strany 38

2.2.5 Email This page is to set Email details for use by NetAgent. Email SettingEmail Server This section is to set NetAgent Email Server . Note t

Strany 40 - NetAgent Utility CD.)

2.2.6 SMS When UPS events occurs, it allows Short Message Signals (“SMS”) to be sent and received using a GSM/GPRS/CDMA Modem. Operation information

Strany 41 - Fig.26 UPS Events

2.2.7 Modem (For 3 Ports NetAgent II only) This section is to configure Modem’s setting if 3 ports NetAgent connects with GSM/GPRS Modem. Modem Settin

Strany 42 - Device Connected

2.2.8 WEB/Telnet This page is to set up the User Account in NetAgent. User Account User Name This section is to set a user name for NetAgent web p

Strany 43

2.2.9 System Time This page is to set NetAgent system time. You can provide NetAgent with up to 2 time servers or you can set a time zone. System Ti

Strany 44 - Fig.28 Email

2.2.9 NetFeeler II (For 3 Ports NetAgent II only) This page is to set Environmental sensors-NetFeeler II’s configurations. NetFeeler II Critical Und

Strany 45

2.6 AC power status _______________________________________ 60 2.7 Battery Status _________________________________________ 60 2.8 Status History ____

Strany 46 - Enter the SIM password

2.2.10 Language This page is to set the language interface for NetAgent. Interface Language This section is to set the language for NetAgent web

Strany 47 - 2.2.8 WEB/Telnet

2.3 Log Information Sub-Menu : 2.3.1 Event Log 2.3.2 SMS 2.3.3 Data Log 2.3.4 Save Data Log NetAgent Log Record Model Log Information Single Port(D

Strany 49 - Fig.32 NetFeeler II

2.3.2 SMS This page is a SMS Event log. It shows a record of all mobile number, giving the Date/Time of the SMS sent and a detailed description of eac

Strany 50 - 2.2.10 Language

2.3.3 Data Log This page is a UPS data log. It records UPS Input Voltage/Output Voltage/ Frequency/ Loading/Capacity/ Temperature. When reach to the l

Strany 51

Fig.37 Date Log 49

Strany 52 - Fig.35 Event Log

2.3.3 Save Data Log This function is to record RS232 UPS’s voltage, frequency, load, capacity, temperature..etc to save as another file for the other

Strany 53 - Fig.36 SMS Log

2.4 Help Sub-Menu : 2.4.1 Search NetAgent 2.4.2 Serial Port Debug 2.4.3 Help 2.4.4 About 2.4.1 Search NetAgent This to display all the found NetA

Strany 54 - 2.3.3 Data Log

2.4.3 Help This to help to illustrate the operation of NetAgent 2.4.4About About This to check Netagent’s Firmware/Hardware version and serial num

Strany 55 - Fig.37 Date Log

Firmware Update Setting Default FTP server is set as ftp.icv99.com with its username/password. Click on Update Now, NetAgent will connects to the FTP

Strany 56 - 2.3.3 Save Data Log

Appendix B -3 Ports NetAgent II with SMS Modem ________________ 87 Appendix C –SMS Server with SMS Modme______________________ 91 4

Strany 57

Chapter 6. Telnet (Remote Configuration) Section1. Introduction NetAgent supports multiple Network Management systems and LAN protocols. After finishi

Strany 58

Fig.42 NetAgent Telnet window 1. Set IP Address. This function allows you to setup IP Address, Gateway Address, Subnet Mask parameters. 2. Set SNMP M

Strany 59

Chapter 7. ClientMate - Windows Shutdown Utility ClientMate is a utility for connecting to NetAgent. This utility is for the Windows platform. When t

Strany 60

2.1 Config When the ClientMate gets the signal from the NetAgent about the AC power failure or battery low signals, the ClientMate will based on the c

Strany 61

vi. Shutdown Windows To configure if shutdown or Sleep the Windows system when power failure. vii. When AC failed, commence computer shutdown sequenc

Strany 62 - Section2. Using ClientMate

2.3 About Press this button could review the version information of the ClientMate, as here bellowed. Fig.47 ClientMate:About 2.4 Event log Press thi

Strany 63

2.5 IP address of connection Status ICON Description Already connect to NetAgent UPS at IP 211.21.67.51 Does not connect to any NetAgent. 2.6

Strany 64

Chapter 8. SNMPView – Windows Based UPS Management System Section1. Introduction SNMPView is a software to remotely monitor and control multiple

Strany 65 - Fig.48 ClientMate:About

Section3. Install SNMPView n Put the NetAgent Utility CD into the CD driver. And execute the SNMPView program. o After installation, there will be a N

Strany 66

Section4. Using SNMPView When use SNMP view at the first time, the system will ask for input the user's name and password. Please enter the defau

Strany 67

Chapter1. Introduction Section1. Features NetAgent is a new generation SNMP (Simple Network Management Protocol) monitoring product. Not only coul

Strany 68 - Section3. Install SNMPView

Section5. SNMPView Buttons When use SNMPView, configuration could be done by all function icons displayed or right click on the mouse to show function

Strany 69 - Section4. Using SNMPView

Following is the main function icons and its reference chapter. Main List Sub List • 5.1.1 Enumerate • 5.1.2 Add Group • 5.1.3 Add UPS • 5.1.4 Dele

Strany 70 - Section5. SNMPView Buttons

5.1 ENUMERATE(D) Start SNMPView and press the “Enumerate” button, SNMPView will start a search for all the NetAgent on network and list them in the m

Strany 71

5.1.4 DELETE UPS Highlight the unit to be deleted from main list and right click on it to choose Delete or use click on the Delete icon from main fu

Strany 72

5.1.7 Import Configuration This is to import the configuration of NetAgent UPS that saved 68

Strany 73

5.1.8 Open archive Event Log Open up “SnmpElog.dat”, SNMPView would show the event log of all NetAgent UPS: Open up “SnmpElog.dat”, event log would

Strany 74 - 5.1.7 Import Configuration

5.1.9 Open archive Data Log Open up “SnmpDlog.dat”, SNMPView would show the event log of all NetAgent UPS: Open up “SnmpDlog.dat”, data log would sh

Strany 75

5.2 View(S) This is to choose the presentation format of NetAgent UPS. 5.2.1 Large Icons Large icon view to display IP address and its location. 5

Strany 76

5.2.3 Details Detailed Information displays NetAgent UPS’s IP address, name, input voltage, output voltage, battery capacity, load, frequency..etc. 5

Strany 77

5.3 Tools(P) Highlight NetAgent UPS device and configure. 5.3.1 Settings General This to configure UPS information, record UPS event, enable trap a

Strany 78

Section2. Applications 2.1 NetAgent makes your UPS on the Internet When the UPS connects with NetAgent, the system manager could check each and every

Strany 79

Trap List Double click on the trap that listed and configure UPS Loading To configure all the other devices and its load that connects with Ne

Strany 81

5.3.2 UPS Monitor Highlight NetAgent UPS device and configure. Or right click on the highlighted device and click on monitor device Meter Display Net

Strany 82

Event Log This display event happened with date/time and its description Control • Turn Off UPS: To shutdown UPS • Reboot UPS: UPS shuts down in 12

Strany 83

Once choose the function that to perform and click on “Execute” Note: UPS must supports those function to perform it Test Control • UPS Self Test: Ex

Strany 84

5.3.3 UPS Management To configure SNMP of its NetAgent UPS 79

Strany 85 - NetAgent UPS

5.4 System(S) To view event log, data log and configuration 5.4.1 Event Log Display event log , date/time and description of all NetAgent UPS 5.4.

Strany 86

5.4.3 SNMP Option To set NetAgent UPS’s parameter 81

Strany 87 - To set NetAgent UPS’s

5.5 User(U) Total of 8 users account can be created to manage and control its NetAgent UPS 5.5.1 Change Password To change existing user’s password t

Strany 88

5.6 Help(H) Display the current SNMPView version, and operation information 5.6.1 HTML Help This to check the operation of SNMPView 5.6.2 About Disp

Strany 89

Fig.1 NetAgent connection Software Fig.2 3 Port NetAgent II Diagram 3

Strany 90

Appendix A - Update the firmware of NetAgent UPS NetAgent provides the following convenient methods for user to update the latest firmware of the Net

Strany 91

2. Use FTP to update (suitable for BK,CK,DK,BP,CP,DP using firmware version 2.35 and later) The FTP is a easy and common way to upload the latest fir

Strany 92

3. Use IE browser to update (suitable for BK,CK,DK,BP,CP,DP version) This method is to enter the account, password and IP address of the NetAgent UPS

Strany 93

Appendix B -3 Ports NetAgent II with SMS Modem BP506 & SMS MODEM Hardware Installation: 1: A:GSM MODEM。 B:GSM MODEM Adaptor 。 C:N

Strany 94

card has password, invalid password. If such conditions happens, please unplug&plug the power on Modem and it shall ready SIM again. If Led doesn

Strany 95

BP506 Modem Configuration: 1、BP506 Modem 2.Modem communication Type→Select SMS 3.SMS Communication→Select GPRS

Strany 96

BP506 SMSConfiguration: BP506→Configuration→1.SMS 2.Select Local Modem 3.Enter BP506’s username and password

Strany 97 - 1. Insert Sim card

Appendix C –SMS Server with SMS Modme GPRS MODEM Installation: 1. Insert Sim card 2、 Connect DC adaptor to GPRS modem as well serial cable p

Strany 98

2:Once installed, the icon would appear on the tool bar 3:Right click on the SMS server icon and check modem status

Strany 99

3、NetAgent sends SMS via modem: 1. Click on SMS in the NetAgent Webpage 2. Enter the SMS server’s IP Service Port:NetAgent & SMS Server po

Komentáře k této Příručce

Žádné komentáře