6. Specifications
PowerWalker VFI
6000C/R LCD
PowerWalker VFI
10000C/R LCD
110 VAC ± 3 % at 50% Load;
176 VAC ± 3 % at 100% Load
Low Line Loss Voltage + 10V
High Line Loss Voltage - 10V
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Synchronized Range)
46Hz ~ 54 Hz @ 50Hz system ; 56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
100%~110%: 10min、110%~130%: 1min、>130% : 1sec
100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec
≦ 3 % @ 100% Linear Load; ≦ 6 % @ 100% Non-linear Load
9 hours recover to 90% capacity
9 hours recover to 90% capacity
Default : 1 A ± 10%
Max.: 2A ± 10%
Depending on applications
16 – 20 (adjustable)
Note: When using internal batteries from 16 to 19, the unit will de-rate according to the
following formula: P = P
Rating
x N/20.
Default: 4 A ± 10%
Max.: 6A ± 10%
273 VDC ± 1% (based on 20pcs batteries)
UPS unit: 580 x 438
x 88 [2U]
Battery pack: 580 x
438 x 133 [3U]
UPS unit: 668 x 438
x 88 [2U]
Battery pack: 580 x
438 x 133 [3U]
UPS unit: 15
Battery pack: 48
UPS unit: 18
Battery pack: 63
0 ~ 40°C
(battery life cycle will be shorten when temperature is above 25°C)
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and
MAC
Power management from SNMP manager and web browser
* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
**If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
***Product specifications are subject to change without further notice.